Part Number Hot Search : 
LM336D MC332980 EMK43H EDZ16 2SC60 BRF10200 HBD682 PE80Q04N
Product Description
Full Text Search
 

To Download MPM-10S-24IS Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 MPM-10IS Series
Board Mount, 10W Single & Dual Output AC/DC Power Supplies
Key Features:
* 10W Output Power * Universal 85-265 VAC Input * EN 60950 Approved * Meets IEC Safety Class II * Industry Standard Pin-Out * Single and Dual Outputs * Meets EN55022 B * >300 kHour MTBF
Electrical Specifications
Specifications typical @ +25C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter Input Voltage Range Input Frequency Input Current Inrush Current EMI Safety Ground Leakage Current Conditions Min. Typ. 85 47 See Model Selection Guide 115 VAC 10.0 230 VAC 20.0 Meets CISPR Pub. 22/FCC Class B 115 VAC 230 VAC Max. 265 440 Units VAC Hz A Pk 0.1 0.3
mA Units
Output
Parameter Output Voltage Output Current Output Voltage Accuracy Line Regulation Load Regulation, Single Output Load Regulation, Dual Output Ripple & Noise (20 MHz) Hold-Up Time Temperature Coefficient Over Voltage Protection Short Circuit Protection, Note 3 Overload Protection, Note 4 Conditions Min. Typ. Max. See Model Selection Guide See Model Selection Guide 1.0 2.0 VIN = Min to Max 0.5 1.0 IO = Min to Max 0.5 1.0 IO = Min to Max 2.5 5.0 3.3V & 5.0 VDC Output 1.5 1.8 All Other Outputs 0.8 1.0 115 VAC, 60 Hz 20 0.02 Zener Diode Clamp 120 Continuous (Autorecovery) Typ. 120% to 180% of Output Power Conditions Input to Output Input to Output, Flash Tested For 60S 500 VDC Conducted Electrostatic Discharge (ESD) RF Field Susceptibility Electrical Fast Transients/Bursts On Mains Surge Min. 3,000 4,700 100 Typ. Max.
% % % % %VP-P of VO mSec %/C % of VO
General
Parameter Isolation Voltage Isolation Test Voltage Isolation Resistance EMI/RFI EMC Compliance Switching Frequency Units VAC VAC M
EN 55022 Level B IEC/EN 61000-4-2 Level 3 IEC/EN61000-4-3 IEC/EN 61000-4-4 Level 3 2 kV IEC/EN 61000-4-5 Level 3 1kV/2 kV 100 kHz Units C C %
MicroPower Direct
292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com
Environmental
Parameter Operating Temperature Range Storage Temperature Range Cooling Humidity Conditions Min. Typ. Max. -25 +25 +71 -40 +85 Free Air Convection (See Derating Curve) RH, Non-condensing 95 Ambient
Physical
Case Size Case Material Weight 2.52 x 1.77 x 0.75 Inches (64.0 x 45.0 x 19.0 mm) Non-Conductive Plastic& Fiberglass (UL94-V0) 3.23 Oz (92g) Conditions Min. Typ. MIL HDBK 217F, 25C, Gnd Benign 300 IEN 60950, IEC 60950 IEN 60950, IEC 60950 IEC 61140 Class II Max. Units kHours
Reliability Specifications
Parameter MTBF Safety Standards Safety Approvals Safety Class
Model Selection Guide
Input Model Number MPM-10S-03IS MPM-10S-05IS MPM-10S-12IS MPM-10S-15IS MPM-10S-24IS MPM-10D-12IS MPM-10D-15IS Current (A) 115 VAC 0.137 0.199 0.191 0.191 0.190 0.172 0.169 230 VAC 0.075 0.075 0.075 0.075 0.075 0.075 0.075 Output 1 (Vout 1) Voltage
(VDC)
Output 2 (Vout 2) Voltage
(VDC)
Current (A) Max. 2.000 2.000 0.833 0.666 0.416 +0.380 +0.300 Min. 0.200 0.200 0.083 0.066 0.042 +0.038 +0.030
Current (A) Max. Min.
Capacitive Load
(F, Max)
Efficiency
(%, Typ)
3.3 5.0 12.0 15.0 24.0 +12.0 +15.0
3,900 3,300 2,200 2,200 1,000 -12.0 -15.0 -0.380 -0.300 -0.038 -0.030 1,000 1,000
70 73 76 76 76 77 77
Other output combinations are available Contact the factory for details at: sales@micropowerdirect.com
Notes: 1. Load regulation is measured for an output change of 0% to 100% at nominal input line. For multiple output models, the loads are balanced. 2. Operation at no-load will not damage these units. However, they may not meet all specifications. 3. Output short circuit protection is provided by a "hiccup mode" circuit. The unit recovers automatically when the fault condition is removed. 4. Output overload protection is provided by a fold back current limiting circuit. 5. The MPM-10IS series includes a built-in 2A/250 VAC fuse. It is recommended that an external 1.5A slow blow fuse also be used on the input for protection.
Derating Curve
Mechanical Dimensions
Pin Connections
Pin Single Dual 1 AC-Neutral AC-Neutral 2 AC-Line AC-Line 3 -Vo -Vo 4 NC Common 5 +Vo +Vo NP = No Connection
Notes: * All dimensions are typical in inches (mm) * Tolerance x.xx = 0.01 (0.25)
MicroPower Direct
www.micropowerdirect.com
*
292 Page Street Ste D Stoughton, MA 02072
TEL: (781) 344-8226
*
FAX: (781) 344-8481
*
E-Mail: sales@micropowerdirect.com


▲Up To Search▲   

 
Price & Availability of MPM-10S-24IS

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .